Home Energy Dashboard — Georgia Power Smart Usage

Annualized Cost

$2,046
$170/mo avg across 13 bills

Latest Bill

$234
May 22–Jun 23, 2026 · 1,306 kWh

Peak Demand (Jun 26)

7.0 kW
Jun 13 Sat 6pm · 92°F · demand setter

Demand Range

3.9–7.0 kW across all 13 billing periods

Peak-Hour kWh

1.82 avg kWh/hr during 2–7pm summer wkdy

Monthly Trend

Monthly Bill vs. Consumption

13 billing periods · Smart Usage plan throughout · Daikin HVAC installed Dec 2024

Bill amount ($) kWh consumed On-peak kWh (2–7pm wkdy Jun–Sep) Monthly Demand (kW billed)

On-Peak vs Off-Peak Energy Split

Jun–Sep only · on-peak window is weekday 2–7pm

Average kWh by Hour of Day — Seasonal Breakdown

Shaded band = on-peak window (2–7pm, weekdays, Jun–Sep only) · family wakeup spike at 6–7am · cooking/HVAC peak at 5pm

Summer (Jun–Aug)

5pm summer spike: 2.54 kWh/hr avg — 3× the overnight base
The 5pm hour (14–18:00 on-peak window) averages 2.54 kWh/hr in summer — the single worst hour. This is HVAC running full blast on a hot afternoon combined with everyone arriving home, cooking, and appliances firing. The on-peak rate multiplier makes this the highest-cost period of the week.

Overnight base is 800–900W — roughly 2× what's expected

The 2–4am floor is 0.59–0.73 kWh/hr (590–730W) in winter and 0.97–1.05 in summer. Expected for a house this size is 200–350W base + HVAC runtime. The gap implies phantom loads or the Daikin running frequently overnight even in mild weather. Worth checking the Skyport app's overnight runtime logs.

6–8am morning ramp is sharp and consistent across all seasons

Usage jumps from 0.8 to 1.3–1.5 kWh/hr at 6am every season — clearly tied to family wakeup (lights, hot water, breakfast). This is off-peak in all seasons. No action needed, but it's useful confirmation that the profile is household-activity driven, not always HVAC.

90 hours ≥4 kW across 13 billing periods

92% off-peak · 59% on weekends (Sat/Sun)

$9.72 per kW/month
every kW avoided saves $10

Near-Peak Hours Per Billing Period

Count of hours that hit ≥4 kW (yellow) and ≥5 kW (red) — the worst months have many near-peak hours, not just one

Hours ≥4 kW Hours ≥5 kW Hour of Day

Day of Week

Saturday + Sunday = 59% of all near-peak events

Behavior Shift — Estimated Savings

Based on $9.72/kW demand rate · annualized from 13 billing periods · demand charge alone, not counting energy savings

Target Required behavior Periods affected Annual savings Effort
Cap at 5.0 kW Avoid only the most extreme spikes (dryer during a heat wave) 5 of 13 ~$46/yr Low
Cap at 4.5 kW Never run dryer while HVAC is actively cooling on hot days 8 of 13 ~$77/yr Medium
Cap at 4.0 kW Full scheduling discipline — dryer 10pm–8am only, pre-cool weekends 12 of 13 ~$120/yr High

Key insight: The dryer (4–5 kW) running while the HVAC is cooling (3–4 kW) is the primary demand spike mechanism. Scheduling laundry for after 10pm or before 8am on hot days is the single highest-leverage behavior change available.

Top 30 Highest Single-Hour Readings

All events ≥4.67 kW · ON-PEAK = weekday 2–7pm Jun–Sep · WEEKEND = Sat/Sun · off-peak weekdays in grey

Date & Time Type kWh Temp Relative load
2026-06-13 Sat 6pm WEEKEND 6.97 92°F
2026-05-17 Sun 6pm WEEKEND 5.99 79°F
2025-07-20 Sun 11am WEEKEND 5.70 89°F
2026-07-02 Thu 9pm OFF-PEAK 5.69 88°F
2025-07-24 Thu 5pm ON-PEAK 5.68 86°F
2026-04-12 Sun 2pm WEEKEND 5.54 84°F
2026-07-01 Wed 11am OFF-PEAK 5.53 91°F
2026-07-02 Thu 8pm OFF-PEAK 5.53 90°F
2025-06-22 Sun 8pm WEEKEND 5.29 87°F
2026-07-02 Thu 10pm OFF-PEAK 5.22 86°F
2026-04-24 Fri 9pm OFF-PEAK 5.13 74°F
2026-06-13 Sat 7pm WEEKEND 5.10 90°F
2026-06-09 Tue 9pm OFF-PEAK 5.09 77°F
2026-06-05 Fri 5pm ON-PEAK 5.07 83°F
2026-05-22 Fri 10pm OFF-PEAK 5.06 70°F
2025-06-22 Sun 4pm WEEKEND 5.05 93°F
2026-06-20 Sat 7pm WEEKEND 4.99 77°F
2026-05-17 Sun 8pm WEEKEND 4.97 73°F
2026-05-30 Sat 5pm WEEKEND 4.96 83°F
2026-05-30 Sat 8am WEEKEND 4.89 73°F
2026-05-17 Sun 7pm WEEKEND 4.86 75°F
2025-12-28 Sun 7pm WEEKEND 4.85 63°F
2026-04-25 Sat 4pm WEEKEND 4.79 74°F
2026-04-12 Sun 5pm WEEKEND 4.77 84°F
2026-06-14 Sun 1pm WEEKEND 4.72 86°F
2025-08-16 Sat 4pm WEEKEND 4.71 91°F
2026-05-17 Sun 4pm WEEKEND 4.71 79°F
2026-05-23 Sat 9pm WEEKEND 4.69 72°F
2026-06-10 Wed 9pm OFF-PEAK 4.68 81°F
2025-07-17 Thu 6pm ON-PEAK 4.67 86°F

Pre-cool strategy: biggest on-peak lever available

Set Daikin to 70–71°F by 1:30pm on summer weekdays. Thermal mass carries the house through the 2–7pm on-peak window at a raised setpoint (76–78°F). At the on-peak rate vs off-peak rate differential, this saves an estimated $50–120/yr depending on summer severity. Available directly in Skyport Home as a schedule setpoint.

Demand charge: never run dryer + HVAC peak cooling simultaneously

An electric dryer pulls 4–5 kW. Your HVAC compressor is 3–4 kW. Together on a hot evening = 7–9 kW in one hour, which sets the month's demand charge. This is the #1 demand reduction lever. Schedule the dryer for after 10pm or before 8am — Skyport won't control the dryer but pairing the two schedules manually is the key move.

Hot weekend afternoons are your worst demand risk

June 13 (Sat, 92°F) set the $234 bill's demand. On hot weekend afternoons (Sat/Sun, 85°F+), proactively pre-cool to 71°F by noon — before you'd normally notice the house warming up. The Skyport weekend schedule should match summer weekday pre-cool timing.

Recommended Daikin (Skyport Home) Thermostat Schedule

Summer (Jun–Sep) weekday

On-peak window highlighted · setpoints in °F · off-peak hours are cheap, peak hours are expensive, demand charge set by any worst hour

Time Temp (°F)
12a 70°
1a 70°
2a 70°
3a 70°
4a 70°
5a 70°
6a 72°
7a 72°
8a 72°
9a 72°
10a 72°
11a 72°
12p 70°
1p 77°
2p 77°
3p 77°
4p 77°
5p 77°
6p 73°
7p 73°
8p 70°
9p 70°
10p 70°
11p 70°

Pre-cool 70°F
Peak setback 77°F
Evening recovery 73°F
Night comfort 70°F

Weekend Schedule (all year)

No on-peak pricing · demand charge still active on hot days

Time Temp (°F)
12a 70°
1a 70°
2a 70°
3a 70°
4a 70°
5a 70°
6a 70°
7a 72°
8a 72°
9a 72°
10a 72°
11a 72°
12p 70°
1p 70°
2p 73°
3p 73°
4p 73°
5p 73°
6p 72°
7p 72°
8p 72°
9p 72°
10p 72°
11p 72°

Winter / Off-Season (Oct–May)

No on-peak hours · flat off-peak energy only · still watch demand

Time Temp (°F)
12a 68°
1a 68°
2a 68°
3a 68°
4a 68°
5a 68°
6a 71°
7a 71°
8a 71°
9a 71°
10a 71°
11a 71°
12p 71°
1p 71°
2p 71°
3p 71°
4p 71°
5p 71°
6p 71°
7p 71°
8p 71°
9p 71°
10p 71°
11p 71°

Skyport Home Setup Steps

Summer Weekday Program

12:30am–6:00am — 70°F (sleep comfort, cheap overnight)
6:00am–1:30pm — 72°F (morning, family active)
1:30pm–2:00pm — 70°F (PRE-COOL: drop hard before peak)
2:00pm–7:00pm — 77°F (ON-PEAK: setback, thermal mass)
7:00pm–10:00pm — 73°F (evening recovery)
10:00pm–12:30am — 70°F (wind-down)

Summer Weekend Program

12:00am–7:00am — 70°F (sleep, off-peak)
7:00am–noon — 72°F (family morning)
Noon–3:00pm — 70°F (PRE-COOL on hot days 85°F+)
3:00pm–8:00pm — 73°F (afternoon, no penalty)
8:00pm–midnight — 72°F (evening comfort)

Rule: Never run dryer during any AC-intensive window