Home Energy Dashboard — Georgia Power Smart Usage
Annualized Cost
$2,046
$170/mo avg across 13 bills
Latest Bill
$234
May 22–Jun 23, 2026 · 1,306 kWh
Peak Demand (Jun 26)
7.0 kW
Jun 13 Sat 6pm · 92°F · demand setter
Demand Range
3.9–7.0 kW across all 13 billing periods
Peak-Hour kWh
1.82 avg kWh/hr during 2–7pm summer wkdy
Monthly Trend
Monthly Bill vs. Consumption
13 billing periods · Smart Usage plan throughout · Daikin HVAC installed Dec 2024
| Bill amount ($) | kWh consumed | On-peak kWh (2–7pm wkdy Jun–Sep) | Monthly Demand (kW billed) |
|---|---|---|---|
On-Peak vs Off-Peak Energy Split
Jun–Sep only · on-peak window is weekday 2–7pm
Average kWh by Hour of Day — Seasonal Breakdown
Shaded band = on-peak window (2–7pm, weekdays, Jun–Sep only) · family wakeup spike at 6–7am · cooking/HVAC peak at 5pm
Summer (Jun–Aug)
5pm summer spike: 2.54 kWh/hr avg — 3× the overnight base
The 5pm hour (14–18:00 on-peak window) averages 2.54 kWh/hr in summer — the single worst hour. This is HVAC running full blast on a hot afternoon combined with everyone arriving home, cooking, and appliances firing. The on-peak rate multiplier makes this the highest-cost period of the week.
Overnight base is 800–900W — roughly 2× what's expected
The 2–4am floor is 0.59–0.73 kWh/hr (590–730W) in winter and 0.97–1.05 in summer. Expected for a house this size is 200–350W base + HVAC runtime. The gap implies phantom loads or the Daikin running frequently overnight even in mild weather. Worth checking the Skyport app's overnight runtime logs.
6–8am morning ramp is sharp and consistent across all seasons
Usage jumps from 0.8 to 1.3–1.5 kWh/hr at 6am every season — clearly tied to family wakeup (lights, hot water, breakfast). This is off-peak in all seasons. No action needed, but it's useful confirmation that the profile is household-activity driven, not always HVAC.
90 hours ≥4 kW across 13 billing periods
92% off-peak · 59% on weekends (Sat/Sun)
$9.72 per kW/month
every kW avoided saves $10
Near-Peak Hours Per Billing Period
Count of hours that hit ≥4 kW (yellow) and ≥5 kW (red) — the worst months have many near-peak hours, not just one
| Hours ≥4 kW | Hours ≥5 kW | Hour of Day |
|---|---|---|
Day of Week
Saturday + Sunday = 59% of all near-peak events
Behavior Shift — Estimated Savings
Based on $9.72/kW demand rate · annualized from 13 billing periods · demand charge alone, not counting energy savings
| Target | Required behavior | Periods affected | Annual savings | Effort |
|---|---|---|---|---|
| Cap at 5.0 kW | Avoid only the most extreme spikes (dryer during a heat wave) | 5 of 13 | ~$46/yr | Low |
| Cap at 4.5 kW | Never run dryer while HVAC is actively cooling on hot days | 8 of 13 | ~$77/yr | Medium |
| Cap at 4.0 kW | Full scheduling discipline — dryer 10pm–8am only, pre-cool weekends | 12 of 13 | ~$120/yr | High |
Key insight: The dryer (4–5 kW) running while the HVAC is cooling (3–4 kW) is the primary demand spike mechanism. Scheduling laundry for after 10pm or before 8am on hot days is the single highest-leverage behavior change available.
Top 30 Highest Single-Hour Readings
All events ≥4.67 kW · ON-PEAK = weekday 2–7pm Jun–Sep · WEEKEND = Sat/Sun · off-peak weekdays in grey
| Date & Time | Type | kWh | Temp | Relative load |
|---|---|---|---|---|
| 2026-06-13 Sat 6pm | WEEKEND | 6.97 | 92°F | |
| 2026-05-17 Sun 6pm | WEEKEND | 5.99 | 79°F | |
| 2025-07-20 Sun 11am | WEEKEND | 5.70 | 89°F | |
| 2026-07-02 Thu 9pm | OFF-PEAK | 5.69 | 88°F | |
| 2025-07-24 Thu 5pm | ON-PEAK | 5.68 | 86°F | |
| 2026-04-12 Sun 2pm | WEEKEND | 5.54 | 84°F | |
| 2026-07-01 Wed 11am | OFF-PEAK | 5.53 | 91°F | |
| 2026-07-02 Thu 8pm | OFF-PEAK | 5.53 | 90°F | |
| 2025-06-22 Sun 8pm | WEEKEND | 5.29 | 87°F | |
| 2026-07-02 Thu 10pm | OFF-PEAK | 5.22 | 86°F | |
| 2026-04-24 Fri 9pm | OFF-PEAK | 5.13 | 74°F | |
| 2026-06-13 Sat 7pm | WEEKEND | 5.10 | 90°F | |
| 2026-06-09 Tue 9pm | OFF-PEAK | 5.09 | 77°F | |
| 2026-06-05 Fri 5pm | ON-PEAK | 5.07 | 83°F | |
| 2026-05-22 Fri 10pm | OFF-PEAK | 5.06 | 70°F | |
| 2025-06-22 Sun 4pm | WEEKEND | 5.05 | 93°F | |
| 2026-06-20 Sat 7pm | WEEKEND | 4.99 | 77°F | |
| 2026-05-17 Sun 8pm | WEEKEND | 4.97 | 73°F | |
| 2026-05-30 Sat 5pm | WEEKEND | 4.96 | 83°F | |
| 2026-05-30 Sat 8am | WEEKEND | 4.89 | 73°F | |
| 2026-05-17 Sun 7pm | WEEKEND | 4.86 | 75°F | |
| 2025-12-28 Sun 7pm | WEEKEND | 4.85 | 63°F | |
| 2026-04-25 Sat 4pm | WEEKEND | 4.79 | 74°F | |
| 2026-04-12 Sun 5pm | WEEKEND | 4.77 | 84°F | |
| 2026-06-14 Sun 1pm | WEEKEND | 4.72 | 86°F | |
| 2025-08-16 Sat 4pm | WEEKEND | 4.71 | 91°F | |
| 2026-05-17 Sun 4pm | WEEKEND | 4.71 | 79°F | |
| 2026-05-23 Sat 9pm | WEEKEND | 4.69 | 72°F | |
| 2026-06-10 Wed 9pm | OFF-PEAK | 4.68 | 81°F | |
| 2025-07-17 Thu 6pm | ON-PEAK | 4.67 | 86°F |
Pre-cool strategy: biggest on-peak lever available
Set Daikin to 70–71°F by 1:30pm on summer weekdays. Thermal mass carries the house through the 2–7pm on-peak window at a raised setpoint (76–78°F). At the on-peak rate vs off-peak rate differential, this saves an estimated $50–120/yr depending on summer severity. Available directly in Skyport Home as a schedule setpoint.
Demand charge: never run dryer + HVAC peak cooling simultaneously
An electric dryer pulls 4–5 kW. Your HVAC compressor is 3–4 kW. Together on a hot evening = 7–9 kW in one hour, which sets the month's demand charge. This is the #1 demand reduction lever. Schedule the dryer for after 10pm or before 8am — Skyport won't control the dryer but pairing the two schedules manually is the key move.
Hot weekend afternoons are your worst demand risk
June 13 (Sat, 92°F) set the $234 bill's demand. On hot weekend afternoons (Sat/Sun, 85°F+), proactively pre-cool to 71°F by noon — before you'd normally notice the house warming up. The Skyport weekend schedule should match summer weekday pre-cool timing.
Recommended Daikin (Skyport Home) Thermostat Schedule
Summer (Jun–Sep) weekday
On-peak window highlighted · setpoints in °F · off-peak hours are cheap, peak hours are expensive, demand charge set by any worst hour
| Time | Temp (°F) |
|---|---|
| 12a | 70° |
| 1a | 70° |
| 2a | 70° |
| 3a | 70° |
| 4a | 70° |
| 5a | 70° |
| 6a | 72° |
| 7a | 72° |
| 8a | 72° |
| 9a | 72° |
| 10a | 72° |
| 11a | 72° |
| 12p | 70° |
| 1p | 77° |
| 2p | 77° |
| 3p | 77° |
| 4p | 77° |
| 5p | 77° |
| 6p | 73° |
| 7p | 73° |
| 8p | 70° |
| 9p | 70° |
| 10p | 70° |
| 11p | 70° |
Pre-cool 70°F
Peak setback 77°F
Evening recovery 73°F
Night comfort 70°F
Weekend Schedule (all year)
No on-peak pricing · demand charge still active on hot days
| Time | Temp (°F) |
|---|---|
| 12a | 70° |
| 1a | 70° |
| 2a | 70° |
| 3a | 70° |
| 4a | 70° |
| 5a | 70° |
| 6a | 70° |
| 7a | 72° |
| 8a | 72° |
| 9a | 72° |
| 10a | 72° |
| 11a | 72° |
| 12p | 70° |
| 1p | 70° |
| 2p | 73° |
| 3p | 73° |
| 4p | 73° |
| 5p | 73° |
| 6p | 72° |
| 7p | 72° |
| 8p | 72° |
| 9p | 72° |
| 10p | 72° |
| 11p | 72° |
Winter / Off-Season (Oct–May)
No on-peak hours · flat off-peak energy only · still watch demand
| Time | Temp (°F) |
|---|---|
| 12a | 68° |
| 1a | 68° |
| 2a | 68° |
| 3a | 68° |
| 4a | 68° |
| 5a | 68° |
| 6a | 71° |
| 7a | 71° |
| 8a | 71° |
| 9a | 71° |
| 10a | 71° |
| 11a | 71° |
| 12p | 71° |
| 1p | 71° |
| 2p | 71° |
| 3p | 71° |
| 4p | 71° |
| 5p | 71° |
| 6p | 71° |
| 7p | 71° |
| 8p | 71° |
| 9p | 71° |
| 10p | 71° |
| 11p | 71° |
Skyport Home Setup Steps
- Daikin system
- Skyport Home app
- Smart Usage billing plan
Summer Weekday Program
12:30am–6:00am — 70°F (sleep comfort, cheap overnight)
6:00am–1:30pm — 72°F (morning, family active)
1:30pm–2:00pm — 70°F (PRE-COOL: drop hard before peak)
2:00pm–7:00pm — 77°F (ON-PEAK: setback, thermal mass)
7:00pm–10:00pm — 73°F (evening recovery)
10:00pm–12:30am — 70°F (wind-down)
Summer Weekend Program
12:00am–7:00am — 70°F (sleep, off-peak)
7:00am–noon — 72°F (family morning)
Noon–3:00pm — 70°F (PRE-COOL on hot days 85°F+)
3:00pm–8:00pm — 73°F (afternoon, no penalty)
8:00pm–midnight — 72°F (evening comfort)